9 Common Subfloor Installation Mistakes—and How to Avoid Them

Advertisement
billboard - default
Sponsored Content Construction Quality

9 Common Subfloor Installation Mistakes—and How to Avoid Them

From tight spacing to improper fasteners, simple errors can lead to callbacks. Here’s a best-practice refresher for subfloor installation


July 13, 2018
LP Legacy OSB subfloor panels

One of the benefits of OSB panels is simple installation. Familiar tools, straightforward methods, and a small bit of attention are all that’s required to ensure a solid subfloor in everyday applications.

Still, as with any product, missing steps or not following instructions when installing can lead to mistakes. And in the case of installing subfloors, those mistakes can mean movement, buckling, squeaks—and potential callbacks. 

Here are a few of the most common mistakes installers make with OSB when installing subfloor and how to avoid them. As always, refer to the manufacturer’s installation instructions for complete details.

How to Install a Subfloor: Avoid These Common Mistakes 

1. Improper Spacing Between Panels

Like any wood product, OSB will expand and contract after installation; without a small gap between panel ends, the expansion could cause buckling. Most manufacturers recommend 1/8 inch at panel ends and edges. For some premium subfloors, 1/16 inch may be enough along panel edges, so refer to the installation instructions. Panels with tongue-and-groove sides will self-gap, as long as they’re not pressed together too tightly (don’t force or hammer TNG sides together). 

Alternatively, don’t leave too much space. If the spacing is wider than 1/8 inch, it could lead to movement and noise. 

The tongue-and-groove sides of LP Legacy premium engineered subfloor are self-gapping to provide the desired 1/16-inch spacing during subfloor installation.
The tongue-and-groove sides of LP Legacy premium engineered subfloor are self-gapping to provide the desired 1/16-inch spacing between panels during subfloor installation. The panels fit together with ease.

 

2. Subfloor Panels Installed Upside-Down 

Panels may be sanded on one or both sides. In all cases, the detailed panel trademark stamp should be installed downward so they can be examined during inspections. Installing some panels with the trademark side up may result in a slightly uneven surface.


RELATED


3. Improper Fastener Placement in Subfloor Panels

Fasten panels using 8d ring-shank nails or other code-approved fasteners. Install fasteners beginning 3/8 inch from panel corner and then 6 inches on-center along the panel edges, and at 12 inches on-center along center supports. Be sure to place all perimeter fasteners 3/8 inch back from the nearest panel edge; this will help reduce the chance of edge swell.

4. Gluing Too Far Ahead

For efficiency, many installers prefer to lay down several panels’ worth of glue at a time, but the time delay could cause the adhesive to skim over, affecting its strength and potential noise. For best results, work no more than one panel ahead. 

5. Not Gluing the Subfloor's Tongue-and-Groove

Applying a small bead of glue in the tongue-and-groove can significantly help reduce any movement and noise. 

6. Delaying Fastening the Panels

Again, it’s tempting to tack the corners and come back to screw all the panels down at once. But by then the glue is already set. Fasten each panel fully as you go to ensure full adhesion and avoid movement and noise down the road. 

7. Using Improper Fasteners

Using code-approved screws rather than nails is the best option for avoiding movement. If using nails for subfloor installation, stick with ring-shank nails; smooth nails may withdraw easier, leading to squeaks. 

8. Letting Water Sit on Subfloor Panels

If the floor system is exposed to the elements and bulk water is present, sweep it off or drill drainage holes. Some subfloor panels come with built-in notches to help drain water. 

 

If bulk water is present on the subflooring panels during subfloor installation, drill drainage holes or sweep the water off.
If bulk water is present on the subflooring panels during subfloor installation, drill drainage holes or sweep the water off. This step isn't required for LP Legacy engineered subfloor panels, which have built-in drainage notches. 

 

9. Improper Storage of Subfloor Panels

Always store panels in a clean, dry area and off the ground. If possible, store panels indoors. If stored outside, cover panels with plastic sheets or tarps. Keep cover open and away from the sides and bottom of the panels to allow for air circulation. Space units at least 4 inches on all four sides. Protect edges to avoid damage to the tongue-and-groove profile. 

A well-installed subfloor is one that homeowners don’t have to think about after they move in. Avoiding these common errors can help ensure your flooring system is stable, quiet, and reliable for years to come. 
 

Advertisement
leaderboard2 - default
Written By
Supply Chain Planning Manager

A licensed Civil Engineer specializing in wood engineering, Allan Burk is the Supply Chain Planning Manager for LP Building Products’ OSB and EWP business. He has worked in R&D, manufacturing and sales throughout his career in the building products industry.

Advertisement
boombox1 -
Advertisement
native1 - default
halfpage2 -

More in Category

Delaware-based Schell Brothers, our 2023 Builder of the Year, brings a refreshing approach to delivering homes and measuring success with an overriding mission of happiness

NAHB Chairman's Message: In a challenging business environment for home builders, and with higher housing costs for families, the National Association of Home Builders is working to help home builders better meet the nation's housing needs

Sure there are challenges, but overall, Pro Builder's annual Housing Forecast Survey finds home builders are optimistic about the coming year

Advertisement
native2 - default
Advertisement
halfpage1 -

Create an account

By creating an account, you agree to Pro Builder's terms of service and privacy policy.


Daily Feed Newsletter

Get Pro Builder in your inbox

Each day, Pro Builder's editors assemble the latest breaking industry news, hottest trends, and most relevant research, delivered to your inbox.

Save the stories you care about

Lorem ipsum dolor sit amet lorem ipsum dolor sit amet lorem ipsum dolor sit amet.

The bookmark icon allows you to save any story to your account to read it later
Tap it once to save, and tap it again to unsave

It looks like you’re using an ad-blocker!

Pro Builder is an advertisting supported site and we noticed you have ad-blocking enabled in your browser. There are two ways you can keep reading:

Disable your ad-blocker
Disable now
Subscribe to Pro Builder
Subscribe
Already a member? Sign in
Become a Member

Subscribe to Pro Builder for unlimited access

Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua.